Periodic HeartBeat fails on Exchange 2013 CU8

In one of our 2 servers in a DAG, we keep getting the warning message:

Event 22004 ShadowRedundancy:
The periodic heartbeat to primary server server.domain.local failed.

However everything seems to work just fine (incl. failover). I haven't found any other logs that indicate problems.
Can some one please point me in the right direction what the issue could be or if it's a known bug?

May 7th, 2015 5:51am

ShadowRedundancy has to deal with the Transport Queue's, and SafetyNet.

Is the Transport service not running on one of your servers?

Free Windows Admin Tool Kit Click here and download it now
May 7th, 2015 6:49pm

Hi Jared,

All services are started on both servers, also it looks like this has started after the upgrade from CU7 to CU8.

May 8th, 2015 5:20am

Hi,

Please check the receive connector configuration in your environment. If there is any useless receive connector, please clear it and keep the default connectors for normal working.

Regards,

Free Windows Admin Tool Kit Click here and download it now
June 18th, 2015 3:18am

Hi,

Please check the receive connector configuration in your environment. If there is any useless receive connector, please clear it and keep the default connectors for normal working.

Regards,

June 18th, 2015 3:18am