Unable to initialize the Microsoft Exchange Information Store service because the clocks on the client and on the server machine are skewed
Each time I restart this exchange server, the Information Store and System Attendant don't start. If It try to manually start the services, I get the follow errors:Event ID 5003:Unable to initialize the Microsoft Exchange Information Store service because the clocks on the client and on the server machine are skewed. This may be caused by a time change either in the client or the server machine, and may require a reboot of that machine. Other than that, verify that your domain is properly configured and is currently online. Event ID 1005: Unexpected error The clocks on the client and server machines are skewed. ID no: 80090324 Microsoft Exchange System Attendant occurred.The clocks on the domain controllers and the exchange server are set to the same time zones. As well, all three clocks are in sync down to the second. Any ideas on what's causing this and how to fix it?
February 12th, 2010 1:58am

Make sure the clock in your system tray shows the same time/date for both the Exchange server and the domain controllers.Also check this out http://www.experts-exchange.com/OS/Microsoft_Operating_Systems/Server/Windows_2003_Active_Directory/Q_22648594.htmlRaj
Free Windows Admin Tool Kit Click here and download it now
February 12th, 2010 2:01am

Run this Command from the Exchange Server Net time \\ADServerName /Set and confirm the action, and then you need to restart the service Microsoft Exchange Active Directory Topology Service and confirm you are not getting the Error 4001 in the event Viewer.
April 17th, 2011 11:45am

Run this Command from the Exchange Server Net time \\ADServerName /Set and confirm the action, and then you need to restart the service Microsoft Exchange Active Directory Topology Service and confirm you are not getting the Error 4001 in the event Viewer.
Free Windows Admin Tool Kit Click here and download it now
April 17th, 2011 11:45am

I've now seen this error twice to two separate installs of Exchange 2010 after installing SP1 RU3. Both environments run Windows 2003 Domain Controllers with Windows 2008 R2 hosting the Exchange 2010 installs and both are using three member DAGs. After about 25 minutes of sitting idle the IS and SA can be started manually. We have a ticket open with Microsoft, but we have not heard anything back yet.
April 26th, 2011 8:02pm

I started seeing this problem after I installed the CAS role on the mailbox server. The mailbox server is in a two-node DAG as well. Often I'd find adjusting the time manually by a small amount then restarting the MSExchangeADTopology service would fix it... at least until the next reboot.
Free Windows Admin Tool Kit Click here and download it now
May 24th, 2011 5:56pm

Anyone get anywhere with this? I have a 4 member dag all with mbx/cas/ht roles. Two members are in our west coast AD site and two are in our east coast site. The clocks are synched, just 3 hours apart due to the time zones. When the east coast servers are rebooted, they throw the skew error above and can't start either the IS or SA service. Boxes are all 2008 r2 sp1 with ex2010sp1 ru4v2, brand new domain and exchange org.
August 11th, 2011 6:13pm

Is the time zone properly configured on each one? All internal operations are supposed to use the GMT time, which is calculated based on the time zone setting. So all servers in your cluster (and really, everything in your domain) should be showing the same GMT.
Free Windows Admin Tool Kit Click here and download it now
August 15th, 2011 5:53pm

Run this Command from the Exchange Server Net time \\ADServerName /Set and confirm the action, and then you need to restart the service Microsoft Exchange Active Directory Topology Service and confirm you are not getting the Error 4001 in the event Viewer. Thank you, it resolved my issue after being sweating looking for solution.
December 24th, 2011 3:01pm

Hy, ia hade the same problem by one of our customers. Ad the fix Above solved the Problem. The Exchange was also a VM hosted on vSphere. The ESX Host had a wrong Time set and however they gave it to the Exchange server. Of Course the "Time Sync" Feature of the vmware tools was disabled. best regards
Free Windows Admin Tool Kit Click here and download it now
April 28th, 2012 2:34pm

Never had this problem untill now. Migrated my (virtual) exchange server with the Mailbox role to another host (with different type of netwerk card ! ? ) The above solution works (also just waiting half hour works), restarting the server brings the problem back Win 2008R2 SP1, Exchange 2010 SP1 latest Rollup Clocks are the same to the second on all servers! Did anybody solved this re-curring problem? ThanksDaniel
April 29th, 2012 4:03am

Run this Command from the Exchange Server Net time \\ADServerName /Set and confirm the action, and then you need to restart the service Microsoft Exchange Active Directory Topology Service and confirm you are not getting the Error 4001 in the event Viewer. Thank you, it resolved my issue after being sweating looking for solution. How can I prevent this from happening? I cannot restart services on each server reboot nor lose 5 years of my life!!! Sokratis Laskaridis MCP, MCTS, MCITP, Small Business Specialist Netapp ASAP, Symantec STS